H261-N80 Gigabyte 2U 4Nodes 24Bays Rackmount Server

 

 

SKU

H261-N80

Processor

(per node)

2nd Generation Intel® Xeon® Scalable and Intel® Xeon® Scalable Processors

Intel® Xeon® Platinum Processor, Intel® Xeon® Gold Processor, Intel® Xeon® Silver Processor and Intel® Xeon® Bronze Processor

CPU TDP up to 165W

NOTE: If only 1 CPU is installed, some PCIe or memory functions might be unavailable

Memory

(per node)

16 x DIMM slots


Total:

64 x DIMM slots

DDR4 memory supported only

6-channel memory architecture

RDIMM modules up to 64GB supported

LRDIMM modules up to 128GB supported

Supports Intel® Optane™ DC Persistent Memory (DCPMM)

1.2V modules: 2933( 1DPC)/2666/2400/2133 MHz


Maximum verified DCPMM configuration:


* Ambient temperature 35°C

* 2nd Generation Intel® Xeon® Scalable processor 165W (Max.)

* DCPMM 256GB x2 pcs (Per Node)


DCPMM installation locations:

DIMM_P1_( G1, J1)


NOTE: 

1. 2933MHz for 2nd Generation Intel® Xeon® Scalable Processors only

2. Intel® Optane™ DC Persistent Memory for 2nd Generation Intel® Xeon® Scalable Processors only

3. The maximum number of DCPMM that can be installed is based on a maximum operating (ambient) temperature of 35°C

4. To enquire about installing a greater number of DCPMM, please consult with our technical or sales representative

Chassis

2U Rackmount Chassis

Dimensions

Chassis Dimensions:

440mm(W) x 87mm(H) x 820mm(D)

HDD Drive Bays

Per node:

4x 2.5" SAS/SATA hot-swappable HDD/SSD bays

2x 2.5" U.2 hot-swappable HDD/SSD bays

Total:

24x 2.5" hot-swappable HDD/SSD bays

16x 2.5" SAS/SATA hot-swappable HDD/SSD bays

8x 2.5" U.2 hot-swappable HDD/SSD bays

SAS card is required for SAS devices support

RAID:

For SATA drives:

Intel® SATA RAID 0/1/5/10

For U.2 drives:

Intel® Virtual RAID On CPU (VROC) RAID 0, 1, 5

Note: VROC module is for Intel®SSD only

Expansion Slots

Per node:

1x Half-length low-profile slot with PCIe x16 (Gen3 x16 bus)

1x Half-length low-profile slot with PCIe x8 (Gen3 x8 bus)

1x OCP mezzanine slot with PCIe Gen3 x16 bus

 

Total:

4x Half-length low-profile slot with PCIe x16 (Gen3 x16 bus)

4x Half-length low-profile slot with PCIe x8 (Gen3 x8 bus)

4x OCP mezzanine slot with PCIe Gen3 x16 bus

Power Supply

2x 2200W redundant PSUs

80 PLUS Platinum

AC Input:

100-127V~/ 14A, 47-63Hz

200-240V~/ 12.6A, 47-63Hz

DC Output:

Max 1200W/ 100-127V~

+12.12V/ 95.6A

+12Vsb/ 3.5A

Max 2200W/ 200-240V

+12.12V/ 178.1A

+12Vsb/ 3.5A

Input Output

Internal I/O:

(Per node)

1x COM header

1x TPM header

1x BMC SGPIO header

1x JTAG BMC header

1x PLD header

1x Clear CMOS jumper

1x IPMB connector

1x Buzzer

Front I/O:

(Per node)

1x Power button with LED

1x ID button with LED

1x Status LED

(Total)

4x Power button with LED

4x ID button with LED

4x Status LED

1x CMC status LED

Only one CMC status LED per system

Rear I/O:

(Per node)

2x USB 3.0

1x VGA

2x RJ45

1x RJ45 MLAN

1x ID LED

(Total)

8x USB 3.0

4x VGA

8x RJ45

4x RJ45 MLAN

4x ID LEDs

1x CMC global management port

Only one CMC global management port per system

Backplane I/O:

24x ports

12Gb/s & 6Gb/s compatible

PCIe Gen3 x4 U.2 port

Cooling

8x 80x80x38mm (16,300rpm) fans

Onboard Devices:

LAN:

Per node:

2x 10Gb/s BASE-T LAN ports (Intel® X550-AT2)

1x Dedicated management port

Total:

8x 10Gb/s BASE-T LAN ports (Intel® X550-AT2)

4x Dedicated management ports

1x 10/100/1000 *CMC global management port

CMC: Chassis Management Controller, to monitor all status of computing nodes.

 

Video:

Integrated in Aspeed® AST2500

2D Video Graphic Adapter with PCIe bus interface

1920x1200@60Hz 32bpp, DDR4 SDRAM

Operating Environment

Operating temperature: 10°C to 35°C

Operating humidity: 8%-80% (non-condensing)

Non-operating temperature: -40°C to 60°C

Non-operating humidity: 20%-95% (non-condensing)

Detail

TPM:

1x TPM header with LPC interface

Optional TPM2.0 kit: CTM000

 

System Management:

Aspeed® AST2500 management controller

Avocent® MergePoint IPMI 2.0 web interface:

Network settings

Network security settings

Hardware information

Users control

Services settings

IPMI settings

Sessions control

LDAP settings

Power control

Fan profiles

Voltages, fans and temperatures monitoring

System event log

Events management (platform events, trap settings, email settings)

Serial Over LAN

vKVM & vMedia (HTML5)

 
H261-N80 Gigabyte 2U 4Nodes 24Bays Rackmount Server
H261-N80 Gigabyte 2U 4Nodes 24Bays Rackmount Server H261-N80 Gigabyte 2U 4Nodes 24Bays Rackmount Server H261-N80 Gigabyte 2U 4Nodes 24Bays Rackmount Server
H261-N80 Gigabyte 2U 4Nodes 24Bays Rackmount Server H261-N80 Gigabyte 2U 4Nodes 24Bays Rackmount Server H261-N80 Gigabyte 2U 4Nodes 24Bays Rackmount Server
H261-N80 Gigabyte 2U 4Nodes 24Bays Rackmount Server
(Click to see larger image and other views)
Standard Features
Configure CPU-1st Node: Intel® Xeon® Scalable Bronze Processor 3104 (1.70 Ghz 85W)
Configure Memory-1st Node: 4x 8GB DDR4 2666 ECC RDIMM Memory
Configure HDD/SSD: 2.5" SATA 6Gb/s 7200RPM 500GB
Configure Warranty: 1 Year Parts Replacement Warranty
Customize